Journeyman Electrician Practice Test -19
Quiz-summary
0 of 10 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
Information
Free online journeyman exam practice test – 19 (NEC and basic Electrical Engineering)
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
1 pointsIf the total ampere of house is 30 which has three branch circuits, what is the minimum size of a branch circuit wire that can be used?
Correct
Incorrect
Note: if the total load is 30 ampere and if it has three or more branch circuits use 60 amp switch and and No.6 wires.
-
Question 2 of 10
2. Question
1 pointsThe distance between service pole and the house building is 120 ft. what is the minimum overhead span wire size?
Correct
Incorrect
Refer : NEC Sec, 224.6(a)
-
Question 3 of 10
3. Question
1 pointsThe emergency power supply in hospital should provide full power within …………. sec of normal power failure.
Correct
Incorrect
-
Question 4 of 10
4. Question
1 pointsIf the battery bank is used as emergency supply, the battery must be of size that will supply the load for a minimum of ………. hours
Correct
Incorrect
-
Question 5 of 10
5. Question
1 pointsThe equivalent of 86 0 F in degree centigrade is ……………………. 0 C.
Correct
Incorrect
Sol : First subtract 32 from the 86 i.e = 86 -32 = 54.
multiply 54 by 5/9 = 54 * (9/5) = 270 / 9 = 30 0C -
Question 6 of 10
6. Question
1 pointsIf five mobile homes are connected to one feeder with an assumed load of 16000 watts each, at 115/230 volts, what is the minimum ampacity of the wires in a feeder circuit?
Correct
Incorrect
Sol : For five mobile homes The demand factor is 33 % ( Table NEC 550 . 31)
16000 * 5 * 0.33 / 230 = 115 amp -
Question 7 of 10
7. Question
1 pointswhat is the power required for lighting the 800 sq ft apartment?
Correct
Incorrect
3 watts of power is required per sq ft for lighting purpose.
so 800 * 3 = 2400 watts. -
Question 8 of 10
8. Question
1 pointswhat is the minimum clearance between two single peace of electrical equipments which are in same sight?
Correct
Incorrect
-
Question 9 of 10
9. Question
1 pointsWhich of the following electrical switching device is utilized to isolate a circuit or equipment from the power supply?
Correct
Incorrect
-
Question 10 of 10
10. Question
1 points…………………………….. is the integral part of the motor which protects the motor from over heating.
Correct
Incorrect