Journeyman Electrician Practice Test-6
Quiz-summary
0 of 20 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
Information
Free online Quiz test on Journeyman electrician exam practice test-6 includes NEC code questions and basic electrical theory.
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 20 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- Answered
- Review
-
Question 1 of 20
1. Question
1 pointsIf a single phase motor full load current is 30 Amperes, what is the dual element fuze size to be used as motor branch circuit short circuit protection?
Correct
Incorrect
Refer: NEC Table 430.52
Dual element fuze size = 175% of FLC
30 * 1.75 = 53 amperes
The next Lower size = 50 Amperes -
Question 2 of 20
2. Question
1 pointsA singe motor is driving 40 volts generator having an over current protection. if the same can also protect the generator when the generator is delivering not more than …………………. percentage of its full load current
Correct
Incorrect
Refer : NEC 445.12[C]
-
Question 3 of 20
3. Question
1 pointsWhat is the derating factor for 4 to 6 conductors grouped in a raceway or cables?
Correct
Incorrect
-
Question 4 of 20
4. Question
1 pointsFor a residence having a single branch circuit with a limited load what is the minimum size of service is required?
Correct
Incorrect
Refer : NEC 230.79[A]
-
Question 5 of 20
5. Question
1 pointsClass II locations are those that are hazardous because of the presence of ………………….
Correct
Incorrect
Refer: NEC 500.6 [B]
-
Question 6 of 20
6. Question
1 pointsFour conductors are made up of four different metals with same dimensions, which of the following metal will offer lower resistance for flow of current?
Correct
Incorrect
-
Question 7 of 20
7. Question
1 pointsIn a Electrical circuit , the lamp resistance is 260 ohms and the ammeter in circuit indicates 5mA. What is the power dissipated in lamp?
Correct
Incorrect
Power = I2R
= (5 mA)2 * 260
= 6.5 mW -
Question 8 of 20
8. Question
1 pointsFuel cell systems should supply emergency load for not less than ……….. hours
Correct
Incorrect
-
Question 9 of 20
9. Question
1 pointsField installed secondary circuit winding for electrical signs of 1000 volts or less shall have a conductor size not less than …………………
Correct
Incorrect
Refer: NEC 600.3.[B]
-
Question 10 of 20
10. Question
1 pointsWhen an electrical circuit tested with ohmmeter, a open circuit is indicated by a reading of ………………….
Correct
Incorrect
-
Question 11 of 20
11. Question
1 pointsWhat is the maximum continuous load that can be connected to 240 volts 10 ampere branch circuit?
Correct
Incorrect
Refer : NEC 210.20
the continuous load should have conductors rated 125% above the connected load.
The maximum permitted load = 10/1.25 = 8 amperes
-
Question 12 of 20
12. Question
1 pointsIf 30 ampere or less snap switches are equipped in panelboards, they must be protected not in excess of:
Correct
Incorrect
Refer: NEC 408.36(A)
-
Question 13 of 20
13. Question
1 pointsHow many watt-meters are required to measure the power in balanced three phase star connected circuit?
Correct
Incorrect
In balanced network power can be measured by a single watt meter placing in between ungrounded conductor and neutral conductor, later the reading can be multiplied by 3 to get the total required power.
-
Question 14 of 20
14. Question
1 pointsIf a DC power supply is supplied to primary of a transformer then …………………….
Correct
Incorrect
-
Question 15 of 20
15. Question
1 pointsThe following lamp holder is approved to be installed in either a damp or wet location?
Correct
Incorrect
Refer: NEC 410.96
-
Question 16 of 20
16. Question
1 pointsIf a 30 amperes snap switch is used as disconnecting means of a 3-horse power motor, what shall be the maximum full load current of the motor?
Correct
Incorrect
Refer: NEC 430.109(C) (2)
If a snap switch is used to disconnect a motor must be derated to 80%
So maximum full load current of motor = 30 * 0.8 = 24 amperes
-
Question 17 of 20
17. Question
1 pointsWhat must be provided for all working spaces above service equipment, switchboards and panel boards?
Correct
Incorrect
Refer: NEC 110.26 (D)
-
Question 18 of 20
18. Question
1 pointsThe voltage shall not be greater than ………….. to supply listed electrical discharge lightening in dwelling units, hotels and motels?
Correct
Incorrect
Refer: NEC 210.6(A)
-
Question 19 of 20
19. Question
1 pointsHow many number of service disconnects per service are allowed to be grouped in any one location?
Correct
Incorrect
Refer: NEC 230.71 (A)
-
Question 20 of 20
20. Question
1 pointsWhat is the minimum standard rating for fuses and inverse time circuit breakers?
Correct
Incorrect
Refer: NEC 260.6
The rating starts with 15 amperes up to 6000 amperes
Wonderful Site.