Journeyman Electrician Practice Test-24
Quiz-summary
0 of 10 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
Information
Take a free online practice exam for journeyman electrician exam- 24
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
1 pointsWhat is the general lighting unit load for a 6000 square foot hospital?
Correct
Incorrect
Sol : Hospital general lighting load = 2 V – A /Sq.Foot (NEC 220.12)
6000 * 2 = 12000 Volt-Ampere
-
Question 2 of 10
2. Question
1 pointsThe calculated lighting load with corresponding demand factors shall not be applied to determine number branch circuits required for wiring.
Correct
Incorrect
Refer: NEC 220.42
-
Question 3 of 10
3. Question
1 pointsDwelling unit has a floor area of 2000 sq ft, what are the minimum number of branch circuits required for lighting load at 115 volt ?
Correct
Incorrect
Refer : NEC 220.22
2000 * 3 = 6000 Volt- Ampere
6000/ 115 = 52.17 amperes
Four 15 amp 2-wire circuits or three 20-amp 2-wire circuits. -
Question 4 of 10
4. Question
1 pointsWhat is the minimum volume of a 4 inch round/octagonal metal box having 1/2 inch depth?
Correct
Incorrect
Refer: NEC Table 314.6
-
Question 5 of 10
5. Question
1 pointsThe conductors shall be protected from abrasion at both entry and exit points of a boxes, conduit bodies and fittings.
Correct
Incorrect
Refer: NEC 314.17 (Entry of the boxes only)
-
Question 6 of 10
6. Question
1 pointsWhich of the total maximum bend that an EMT conduit can be bend?
Correct
Incorrect
Refer: NEC 358.36
-
Question 7 of 10
7. Question
1 pointsThe electrical wire has a resistance of 1.5 ohms has a current flow of 4 amp. If supply end of the electrical wire indicates 120 volts what will the voltmeter reading of at the end of the wire?
Correct
Incorrect
120 – 1.5*4 = 114 volts
-
Question 8 of 10
8. Question
1 pointsAirfield lighting cable used in electrical circuit rated over 5000 volts and powered by electrical regulator shall be permitted to be non-shielded.
Correct
Incorrect
Refer : NEC 310.E
-
Question 9 of 10
9. Question
1 pointsA 120/240 single family dwelling unit has a calculated demand load of 120 amperes, what is the minimum type of THW copper conductor size allowed?
Correct
Incorrect
Refer : NEC Table 310.15(B)
-
Question 10 of 10
10. Question
1 pointsWhat is the equivalent resistance offered by parallel connection of two resistors each having 2 ohms of resistance?
Correct
Incorrect
( 2 * 2) (2+2) = 1 ohm