Journeyman Electrician Practice Test-3
Quiz-summary
0 of 15 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
Information
Free online quiz test journeyman exam -3 includes NEC questions and basic electrical theory.
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsThe power systems and branch circuits are grounded to limit …………………………
Correct
Incorrect
When a lighting surge or any fault occurs on circuit then a high voltage surge will induce in it which can destroy the circuit. So the high voltage is routed to ground by properly grounding it.
-
Question 2 of 15
2. Question
1 pointsEMT shall be securely fastened in place at least every …………..
Correct
Incorrect
Refer: NEC 358.30(A)
-
Question 3 of 15
3. Question
1 pointsHow shall be the insulated or bare busbars mounted in panel boards?
Correct
Incorrect
Refer: NEC 408.51
-
Question 4 of 15
4. Question
1 pointsA single family dwelling unit has a branch circuit lighting load of 1,90,000 VA. What is the demand load of a dwelling unit after the demand factor applied?
Correct
Incorrect
Solution :
Demand factor for first 3000 is 100% so = 3000 VA
Demand factor for load Between 3000 to 120000VA is 35% = 117000 * 0.35 = 40,950
Demand factor for load above 120000VA is 25% = 70000 * 0.25 = 17500
Total demand load= 3000 + 40950 + 17500 = 61450. -
Question 5 of 15
5. Question
1 pointsIf the resistance of branch circuit conductor decreases, the circuit current will ……………
Correct
Incorrect
-
Question 6 of 15
6. Question
1 pointsWhat is the maximum allowable ampacity of a NO.6 AWG copper type THW conductor at an ambient temperature of 75 oC?
Correct
Incorrect
Refer: NEC Table 310.16
-
Question 7 of 15
7. Question
1 pointsPipe electrodes shall have resistance to ground not to exceed …………. ohms when used alone.
Correct
Incorrect
-
Question 8 of 15
8. Question
1 pointsThe maximum voltage rating of plug fuse is ………….. volts
Correct
Incorrect
Refer: 240.5 [A]
-
Question 9 of 15
9. Question
1 pointsThe ampacity of branch circuit conductors between the controller and multi speed motor shall not be less than ………….. percent of the current rating of the windings.
Correct
Incorrect
Refer : 430.21[B]
-
Question 10 of 15
10. Question
1 pointsAutomatic transfer switches rated not less than ……………….. shall be listed for emergency system use.
Correct
Refer : 700.5[C]
Incorrect
-
Question 11 of 15
11. Question
1 pointsWhat is the current flow of a 3 kW heat strip connected to 120 volts ac power supply?
Correct
Incorrect
Power = E * I
I = 3 kW / 120
I = 3000 / 120 = 25 ampers
-
Question 12 of 15
12. Question
1 pointsIf the resistance of two 12 AWG conductors of 175 feet is 0.4 ohms (0.2 ohms each). What is the power loss in a conductor when the current flow of conductor is 18 amperes?
Correct
Incorrect
Power Loss = I2 R
= 182 * 0.4 = 129.6 watts
-
Question 13 of 15
13. Question
1 pointsWhich of the following meter is used to measure resistances in the circuit?
Correct
Incorrect
-
Question 14 of 15
14. Question
1 pointsThe transformer output power is 136 VA, what is transformer input power if the transformer efficiency is 85%?
Correct
Incorrect
Transformer efficiency = 85% 0r 0.85
output power / input power = 0.85
input power = 136 VA / 0.85 = 160 VA
-
Question 15 of 15
15. Question
1 pointsWhat is the measuring unit of circuit resistance represented by a letter R?
Correct
Incorrect