Journeyman Electrician Practice Test-7
Quiz-summary
0 of 15 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
Information
Free online practice test on Journeyman Electrician Exam includes questions from NEC and Basic Electrical theory.
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- Answered
- Review
-
Question 1 of 15
1. Question
1 pointsA NO.6 THW conductor is placed in a room where the ambient temperature of room is 520C. What is its allowable ampacity?
Correct
Incorrect
NO . 6 THW ampacity at 750C is 65 amperes
Refer : NEC 310.15(B)(2)(b)
Ambient derating factor at 520C is 0.76
So 0.76 * 65 = 49.44 amperes close to 50 amperes -
Question 2 of 15
2. Question
1 pointsThe Minimum working clear distance in front of the enclosed equipment operating at a voltage 240 volts is ……………. feet
Correct
Incorrect
Refer: NEC 110.26[A][2]
-
Question 3 of 15
3. Question
1 pointsDead ends of metal wireways need not be closed.
Correct
Incorrect
Refer: NEC 376.58
-
Question 4 of 15
4. Question
1 pointsThe conductors sized 1/0 AWG or smaller shall be permitted to be run in parallel for frequencies higher than ………………. HZ.
Correct
Incorrect
-
Question 5 of 15
5. Question
1 pointsThe motor ground fault protective device need to be capable of carrying the starting current of the motor.
Correct
Incorrect
Refer: NEC 430.53[B]
-
Question 6 of 15
6. Question
1 pointsIn an electrical circuit the power dissipation in a resistor will be 1.2 W, which of the following resistor is best suitable to use under this power dissipation.
Correct
Incorrect
Refer : Basic Electrical Theory
1/8 Wt to 2 Wt -> carbon film
1/4 Wt –> metal Film
low power –> Thick film
2Wt or more = wire wound -
Question 7 of 15
7. Question
1 pointsWhat type of lamp holders required in a branch circuit has the rating of 20 amp or more?
Correct
Incorrect
Refer : NEC 210.21[A]
-
Question 8 of 15
8. Question
1 pointsIn wet area a raceway, fittings shall be spaced not less than ………..inch
Correct
Incorrect
Refer: NEC 300.6[D]
-
Question 9 of 15
9. Question
1 pointsWhat is the smallest size of conductor for power work as per NEC?
Correct
Incorrect
-
Question 10 of 15
10. Question
1 pointsThe minimum thickness of the sealing compound of completed seal conduit, except where it is used in cables shall not be less than ………… mm
Correct
Incorrect
Refer : NEC 501.15[C][3]
-
Question 11 of 15
11. Question
1 pointsWorking space in rooms allocated for electrical equipment shall not be used for …………………..
Correct
Incorrect
Refer : NEC 110.26(B)
-
Question 12 of 15
12. Question
1 pointsAn ohm meter connected across a 120 volts electrical heater shows 7.5 ohms, how much current the heater draws?
Correct
Incorrect
Current = E / R = 120 / 7.5 = 16
-
Question 13 of 15
13. Question
1 pointsHow many sets of 3 wire feeders shall be permitted to utilize a common neutral?
Correct
Incorrect
Refer : NEC 215.4
-
Question 14 of 15
14. Question
1 pointsIn which of the following the panel boards must be enclosed?
Correct
Incorrect
Refer NEC 408.38
-
Question 15 of 15
15. Question
1 pointsThe maximum wattage of incandescent-lamps must not exceed …………… that may be used on medium bus lampholders.
Correct
Incorrect
Refer: NEC 410.103
Like the tests but some of the questions are a bit vague.
Great post, thanks for sharing!