Question 1 of 10
1. Question
A single family dwelling unit has a connected load of 4000 VA. which of the following is the calculated demand load?
Correct
Incorrect
Refer : NEC Table 220.42
First 3000 VA the demand factor is 100% = 3000 * 100 % = 3000 VA
remaining (4000-3000) = 1000 ( demand factor = 35%) = 1000 * 0.35 = 350 VA
total demand load = 3000 + 350 = 3350 VA -
Question 2 of 10
2. Question
What is the adjustment ampacity of a 3/0 THWN conductor at an ambient temperature of 1080F in wet location. The raceway contains four 3/0 THWN conductors in it.
Correct
Incorrect
3/0 THWN conductor ampacity in wet location (750C) = 175 Amperes ( NEC 310.15(B)(16))
Ambient temperature correction factor at 1080F = 0.85 ( NEC 310.15(B)(2))
raceway conductor bundle adjustment factor for 4 conductors= 0.8 ( NEC 310.15(B)(3)(a))The conductor ampacity = 175 * 0.85 * 0.8 = 119 Amperes.
-
Question 3 of 10
3. Question
In a dwelling unit has an electric heater rated at 5040 watts at 240 volts. What of the circuit breaker is used to protect the circuit?
Correct
Incorrect
Rated current flow through heater = 5040/240 = 21 amperes
Because 21 is not a standard circuit breaker rating, next higher standard rating is 25 ampere.
-
Question 4 of 10
4. Question
Which of the following locations type NM cable can be permitted to use?
Correct
Incorrect
Refer : NEC 334.12
-
Question 5 of 10
5. Question
In an underground service a bare neutral conductor can be buried in the ground with out any insulation.
Correct
Incorrect
Refer: NEC 230.30
-
Question 6 of 10
6. Question
When two or more single phase electric ranges are supplied by a 3 phase , 4 wire feeder, the total load computed is on the basis of ………………………….
Correct
Incorrect
Refer : NEC 250.55
-
Question 7 of 10
7. Question
What is the unit load per square foot in volt ampere for a restaurant?
Correct
Incorrect
Refer: NEC Table 220.12
-
Question 8 of 10
8. Question
What is permissible voltage drop in percentage for feeders at the farthest outlet of power heating and lighting loads?
Correct
Incorrect
Refer: NEC 215.2(A) (4)
-
Question 9 of 10
9. Question
At least one 15 or 20 ampere receptacle should be located within 50 feet of electrical service applies to outdoor service equipment.
Correct
Incorrect
-
Question 10 of 10
10. Question
The overall length of the power supply cards for mobile homes shall not be less than ………… feet
Correct
Incorrect
Refer : NEC 550.10(D)