Question 1 of 9
1. Question
1 pointsThe ampacity of the feeder tap conductors not less than 10 ft shall not be less than the rating of its terminating device.
Correct
Incorrect
Refer : NEC 249.21[B][1][1]
-
Question 2 of 9
2. Question
1 pointsThe ampacity of the feeder tap conductors which leaves the enclosure or vault shall not be less …………………… of the over current protection device rating protecting the feeder tap conductors.
Correct
Incorrect
Refer : NEC 240.21 [B][1][4]
-
Question 3 of 9
3. Question
1 pointsThe branch circuit rated circuit breaker is marked for use with No 18 AWG and supplies a continuous load of 5.6 ampere, which of the following over current protection amperage that can be used?
Correct
Incorrect
Refer NEC 240.4 D(1)
-
Question 4 of 9
4. Question
1 pointsThe over current device should be connected in parallel with each ungrounded conductor.
Correct
Incorrect
It should be connected in series with each ungrounded conductor so that when the current flow in conductor increases the trip level it trips.
-
Question 5 of 9
5. Question
1 pointsNormally over current devices are located in ungrounded conductors at a point where the conductors deliver the energy to the load.
Correct
Incorrect
Refer : NEC 240.21
It is located near supply end. -
Question 6 of 9
6. Question
1 pointsWhich of the following is the maximum voltage that a plug fuses are used as over-current protection devices in electric circuit?
Correct
Incorrect
-
Question 7 of 9
7. Question
1 pointsWhich of the following is not a standard rating of a fuse or circuit breaker?
Correct
Incorrect
-
Question 8 of 9
8. Question
1 pointsWhen two different sizes of wire are connected in series, the maximum fuse rating that shall be used is one that protects …………………
Correct
Incorrect
-
Question 9 of 9
9. Question
1 pointsOver current protection is not required at the point where the wire size is not over 25 feet.
Correct
Incorrect
Refer : NEC 240.21